Key specs from the product description
- Bandwidth (-3 dB)
- 350 MHz
- Analog channels
- 4 + EXT
- Sample rate (max)
- 4 GSa/s interleaved; 2 GSa/s non-interleaved
- Memory depth
- 400 Mpts/ch (single-ch interleaved); 200 Mpts dual; 100 Mpts/ch non-interleaved
- Vertical resolution
- 12-bit; up to 16-bit in ERES mode
- Rise time (typical, 50 ohm)
- 830 ps
Need a formal quote or a volume price?
For purchase orders, proforma invoices or several units. We typically reply within one working day.
- 1Send the requestTakes a minute
- 2Get your priceTypically one working day
- 3Pay, we shipCard or bank transfer
- 30-day money-back if the item arrives defective, damaged or wrong. Policy
- Traceable calibration documentation ships with instruments
- Pay by card or bank transfer, invoice on request
- We ship worldwide. Destination confirmed with your quote
Datasheets & manuals
Siglent SDS3034X HD Digital Oscilloscope
Overview
The SDS3034X HD belongs to Siglent's SDS3000X HD series of 12-bit digital storage oscilloscopes. It offers a 350 MHz analog bandwidth across four analog channels plus an external trigger input, with sample rates of up to 4 GSa/s in interleaved mode and 2 GSa/s per channel. Memory depth reaches 400 Mpts per channel in single-channel interleaved operation, letting engineers capture long records at high resolution without sacrificing timing detail.
Siglent's SPO display technology delivers waveform capture rates up to 200,000 waveforms per second in normal mode and up to 890,000 waveforms per second in sequence mode, with 256-level intensity grading. The instrument decodes serial buses such as I2C, SPI, UART, CAN and LIN as standard, while CAN FD, FlexRay, I2S, MIL-STD 1553B and other protocols are available as options. Analysis tools include history mode, mask test, Bode plot, power analysis, a digital voltmeter and a counter. A 16-channel logic probe and a 50 MHz arbitrary waveform generator module can be added for mixed-signal and stimulus work.
Features
- 350 MHz bandwidth on 4 analog channels (plus EXT input)
- 12-bit ADC, up to 16 bits in ERES mode
- Sample rate up to 4 GSa/s interleaved, 2 GSa/s non-interleaved
- Up to 400 Mpts/ch record length
- 200,000 wfm/s capture rate (890,000 wfm/s in sequence mode)
- Serial trigger and decode: I2C, SPI, UART, CAN, LIN standard
- 10.1-inch capacitive multi-touch display, 1024 x 600
- USB 3.0 host x2, USB device, and Gigabit LAN with web control
Applications
- Embedded systems debug with serial bus triggering and decoding
- Power electronics analysis, including Bode plots and power measurements
- Long-record transient capture in R&D and validation labs
Siglent SDS3034X HD Digital Oscilloscope Technical Specifications
| Bandwidth (-3 dB) | 350 MHz |
|---|---|
| Analog channels | 4 + EXT |
| Sample rate (max) | 4 GSa/s interleaved; 2 GSa/s non-interleaved |
| Memory depth | 400 Mpts/ch (single-ch interleaved); 200 Mpts dual; 100 Mpts/ch non-interleaved |
| Vertical resolution | 12-bit; up to 16-bit in ERES mode |
| Rise time (typical, 50 ohm) | 830 ps |
| Waveform capture rate | 200,000 wfm/s normal; 890,000 wfm/s sequence |
| Trigger types | Edge, slope, pulse width, window, runt, interval, dropout, pattern, qualified, Nth edge, setup/hold, delay, video, serial |
| Serial decode (standard) | I2C, SPI, UART, CAN, LIN |
| Display | 10.1-inch TFT LCD capacitive touch, 1024 x 600 |
| Interfaces | 2x USB 3.0 host, 1x USB 2.0 host, USB 3.0 device, 10M/100M/1000M LAN |
| Standard probes | One 500 MHz passive probe per channel |
| Options | 16-channel logic probe (1 GSa/s); 50 MHz AWG module (SAG1021I) |
Manufacturer information: Siglent SDS3034X HD product page and SDS3000X HD datasheet
Price $2,390.00 USD as listed on 26 Nov 2026. Request a firm quote: https://indomultimeter.net/products/siglent-sds3034x-hd-digital-oscilloscope-4-channel-350-mhz-4-gsa-s-12-bit
Shipping. We ship worldwide. See the shipping policy.
Documents. Instruments ship with calibration documentation traceable to national standards. Some models, such as the Mensor CPG2500, also ship with an A2LA accredited ISO/IEC 17025 certificate.
Warranty. See the warranty policy.
Before you order
Is the price final?
The price shown is our current price in USD. Your quote confirms price and availability for your quantity.
How is my item supplied?
Items are ordered from the manufacturer for you. The quote confirms availability. Typical response is within one working day.
Do you provide calibration certificates?
Instruments ship with calibration documentation traceable to national standards. Ask in your request if you need a specific certificate.
How can I pay?
By card or by bank transfer. We can send a proforma invoice for your purchasing department.
Do you ship to my country?
We ship worldwide. Put your destination country in your enquiry and we confirm delivery with your quote.
What if it arrives defective, damaged or wrong?
You get a 30-day money-back guarantee for items that arrive defective, damaged or wrong. See the refund policy.