{"product_id":"siglent-f604ms-vna-calibration-kit-oslt-3-5-mm-male-dc-to-9-ghz","title":"Siglent F604MS VNA Calibration Kit, OSLT, 3.5 mm Male, DC to 9 GHz","description":"\u003ch2\u003eSiglent F604MS VNA Calibration Kit\u003c\/h2\u003e\n\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThe F604MS is Siglent's economy 3.5 mm male mechanical calibration kit for vector network analyzer measurements. It provides the four classic standards needed for a full one-port calibration: open, short, fixed 50 ohm load and a 3.5 mm male-to-male through adapter. All standards are specified from DC to 9 GHz, with open and short phase deviation within ±0.8° and a load SWR of no more than 1.032, corresponding to a return loss of at least 36 dB.\u003c\/p\u003e\u003cp\u003eThe through adapter is rated SWR ≤1.06 from DC to 9 GHz (and ≤1.1 from 9 to 26.5 GHz) with insertion loss of 0.1 dB or less and an electrical delay of 82.0 ps. Performance is very similar to the Keysight 85033E mechanical calibration kit, so the F604MS can be used as an approximate replacement and is accepted in the calibration-kit lists of the SVA1000X series and other compatible Siglent analyzers. The discrete standards carry 1 W and use IEC 60169-23 interfaces with a durability of more than 2,000 connections.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOSLT mechanical calibration standards, 3.5 mm male\u003c\/li\u003e\n\u003cli\u003eSpecified from DC to 9 GHz in a 50 ohm system\u003c\/li\u003e\n\u003cli\u003eLoad SWR ≤1.032 (return loss ≥36 dB)\u003c\/li\u003e\n\u003cli\u003eOpen and short phase deviation ≤±0.8°\u003c\/li\u003e\n\u003cli\u003eMale-to-male through adapter with 82.0 ps electrical delay\u003c\/li\u003e\n\u003cli\u003eSimilar performance to the Keysight 85033E kit\u003c\/li\u003e\n\u003cli\u003eSupported calibration kit for SVA1000X series VNAs\u003c\/li\u003e\n\u003cli\u003eOver 2,000-connection durability with 0.9 Nm torque\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eVector network analyzer error correction before S-parameter measurements\u003c\/li\u003e\n\u003cli\u003eFixture and cable characterization in RF laboratories\u003c\/li\u003e\n\u003cli\u003eRoutine verification of RF test setups\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSiglent F604MS VNA Calibration Kit Technical Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCalibration standards\u003c\/th\u003e\n\u003ctd\u003eOpen, short, load and through (OSLT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector\u003c\/th\u003e\n\u003ctd\u003e3.5 mm, male\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eImpedance\u003c\/th\u003e\n\u003ctd\u003e50 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency range\u003c\/th\u003e\n\u003ctd\u003eDC to 9 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOpen phase deviation\u003c\/th\u003e\n\u003ctd\u003e≤±0.8° (DC to 9 GHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShort phase deviation\u003c\/th\u003e\n\u003ctd\u003e≤±0.8° (DC to 9 GHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLoad SWR\u003c\/th\u003e\n\u003ctd\u003e≤1.032 (return loss ≥36 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eThrough SWR\u003c\/th\u003e\n\u003ctd\u003e≤1.06 (DC to 9 GHz); ≤1.1 (9 to 26.5 GHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eThrough insertion loss\u003c\/th\u003e\n\u003ctd\u003e≤0.1 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eThrough electrical delay\u003c\/th\u003e\n\u003ctd\u003e82.0 ps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInterface standard\u003c\/th\u003e\n\u003ctd\u003eIEC 60169-23\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower handling\u003c\/th\u003e\n\u003ctd\u003e1 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTorque \/ key size\u003c\/th\u003e\n\u003ctd\u003e0.9 Nm, 8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e−15 °C to +35 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eManufacturer information: \u003ca href=\"https:\/\/siglentna.com\/product\/f604ms-male-9-ghz-3_5mm-calibration-kit\/\" target=\"_blank\" rel=\"noopener\"\u003eSiglent F604MS official product page\u003c\/a\u003e\u003c\/p\u003e","brand":"Siglent","offers":[{"title":"Default Title","offer_id":67776261554363,"sku":"IMM_VEQRNOX_EC_0173","price":1234.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0777\/2635\/1547\/files\/f604ms_01_0822-600x600-1.jpg?v=1792552388","url":"https:\/\/indomultimeter.net\/products\/siglent-f604ms-vna-calibration-kit-oslt-3-5-mm-male-dc-to-9-ghz","provider":"Indo Multimeter","version":"1.0","type":"link"}