{"product_id":"madgetech-voltx12-3-2v-voltage-data-logger-12-channel-3-2-v-range","title":"MadgeTech VoltX12-3.2V Voltage Data Logger, 12-Channel, ±3.2 V Range","description":"\u003ch2\u003eMadgeTech VoltX12-3.2V Voltage Data Logger, 12-Channel, ±3.2 V Range\u003c\/h2\u003e\n\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe VoltX Series comes in 4-, 8-, 12- and 16-channel versions with 160 mV, 3.2 V and 32 V range options, and the VoltX12-3.2V is the 12-channel model tuned to the ±3.2 V span. Voltage resolution is 0.0004 mV on this range with a calibrated accuracy of ±0.0032 V, so small changes in transducer or battery output remain visible over long recordings. Each channel has its own status LED, and the logger stores 232,903 readings in its 12-channel memory configuration.\u003c\/p\u003e\n\u003cp\u003eData is downloaded over a standard USB-A to Micro USB cable through MadgeTech software, which provides graphical, tabular and statistical views, engineering-unit conversion and automatic export to Excel for further calculation. The black anodized aluminum housing measures 65.6 × 184.2 × 42.7 mm, runs from -20 to +60 °C at up to 95 %RH non-condensing, and the battery provides about 18 months of continuous logging. This model (part number 902185-00) is the direct replacement for the OctVolt and QuadVolt multi-channel voltage loggers.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e12 DC voltage channels over a ±3.2 V measurement range\u003c\/li\u003e\n\u003cli\u003e0.0004 mV resolution with ±0.0032 V calibrated accuracy on the 3.2 V range\u003c\/li\u003e\n\u003cli\u003e4 Hz maximum reading rate down to one reading every 24 hours\u003c\/li\u003e\n\u003cli\u003e232,903-reading memory on the 12-channel model; unused channels can be disabled\u003c\/li\u003e\n\u003cli\u003ePer-channel LEDs plus two status LEDs for at-a-glance confirmation\u003c\/li\u003e\n\u003cli\u003e18-month battery life in a black anodized aluminum enclosure\u003c\/li\u003e\n\u003cli\u003eUSB-A to Micro USB connection works directly with MadgeTech software\u003c\/li\u003e\n\u003cli\u003eIncludes a standard calibration certificate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMonitoring transducer and sensor voltage outputs over long test runs\u003c\/li\u003e\n\u003cli\u003eProfiling DC supply and battery output during development and QA testing\u003c\/li\u003e\n\u003cli\u003eMulti-point voltage trending on production and validation benches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat's in the Box\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUSB-A to Micro USB cable\u003c\/li\u003e\n\u003cli\u003eUniversal power adapter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMadgeTech VoltX12-3.2V Voltage Data Logger, 12-Channel, ±3.2 V Range Technical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eChannels\u003c\/th\u003e\n\u003ctd\u003e12 (individually enable\/disable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage range\u003c\/th\u003e\n\u003ctd\u003e±3.2 V (series also offers ±160 mV and -8 to +32 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage resolution\u003c\/th\u003e\n\u003ctd\u003e0.0004 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage calibrated accuracy\u003c\/th\u003e\n\u003ctd\u003e±0.0032 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReading rate\u003c\/th\u003e\n\u003ctd\u003e4 Hz up to 1 reading every 24 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMemory\u003c\/th\u003e\n\u003ctd\u003e232,903 readings (12-channel model)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBattery life\u003c\/th\u003e\n\u003ctd\u003e18 months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating environment\u003c\/th\u003e\n\u003ctd\u003e-20 to +60 °C, 0 to 95 %RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003eBlack anodized aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e65.6 × 184.2 × 42.7 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003e902185-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003eManufacturer information: \u003ca href=\"https:\/\/www.madgetech.com\/products\/voltx\/\" target=\"_blank\" rel=\"noopener\"\u003eMadgeTech VoltX Series product page\u003c\/a\u003e.\u003c\/p\u003e","brand":"MadgeTech","offers":[{"title":"Default Title","offer_id":67777171751099,"sku":"IMM_21694517","price":700.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0777\/2635\/1547\/files\/madgetech-voltx16-160mv-4-600x600-1.jpg?v=1792557125","url":"https:\/\/indomultimeter.net\/products\/madgetech-voltx12-3-2v-voltage-data-logger-12-channel-3-2-v-range","provider":"Indo Multimeter","version":"1.0","type":"link"}