{"product_id":"keysight-n4433d-003-010-ecal-module-300-khz-to-26-5-ghz-4-port-3-5-mm","title":"Keysight N4433D\/003\/010 ECal Module, 300 kHz to 26.5 GHz, 4-Port, 3.5 mm","description":"\u003ch2\u003eKeysight N4433D\/003\/010 ECal Module\u003c\/h2\u003e\n\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe Keysight N4433D is a four-port RF electronic calibration (ECal) module that brings single-connection calibration to Keysight vector network analyzers. Option 003 defines its frequency coverage from 300 kHz to 26.5 GHz, and Option 010 equips the module with four 3.5 mm female connectors. Inside, the module is a solid-state device with programmable, highly repeatable impedance states that are traceable through a National Metrology Institute, so the standards replace a tray of mechanical opens, shorts, loads and thru connections.\u003c\/p\u003e\n\u003cp\u003eThe analyzer firmware drives the module directly over USB, which removes most of the manual steps that make traditional calibrations slow and error-prone. Connector wear on both the test ports and the calibration standards drops because each calibration requires fewer make-and-break cycles. Where broadband device modeling or time-domain and signal-integrity analysis is needed, Option 0DC extends the calibration range all the way down to DC on the same hardware.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFull four-port calibration in less than half the time of a mechanical cal kit\u003c\/li\u003e\n\u003cli\u003eFrequency coverage from 300 kHz to 26.5 GHz with Option 003\u003c\/li\u003e\n\u003cli\u003eFour 3.5 mm female connectors fitted on the module (Option 010)\u003c\/li\u003e\n\u003cli\u003eSupports female-female, male-male or female-male connector mixing\u003c\/li\u003e\n\u003cli\u003eDirect control from Keysight vector network analyzers via USB\u003c\/li\u003e\n\u003cli\u003eSolid-state, programmable and highly repeatable impedance states\u003c\/li\u003e\n\u003cli\u003eOption 0DC extends calibration down to DC for broadband modeling\u003c\/li\u003e\n\u003cli\u003eReduces connector wear and operator error versus mechanical kits\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFull four-port S-parameter calibration of Keysight VNAs in production test\u003c\/li\u003e\n\u003cli\u003eBroadband device modeling with the DC extension of Option 0DC\u003c\/li\u003e\n\u003cli\u003eSignal-integrity and enhanced time-domain analysis on network analyzers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKeysight N4433D\/003\/010 ECal Module Technical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency range\u003c\/td\u003e\n\u003ctd\u003e300 kHz to 26.5 GHz (Option 003)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of ports\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectors\u003c\/td\u003e\n\u003ctd\u003eFour 3.5 mm female on module (Option 010)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector configurations\u003c\/td\u003e\n\u003ctd\u003eFemale-female, male-male or female-male\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl interface\u003c\/td\u003e\n\u003ctd\u003eDirect USB connection from Keysight VNAs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration technology\u003c\/td\u003e\n\u003ctd\u003eSolid-state ECal with programmable impedance states\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTraceability\u003c\/td\u003e\n\u003ctd\u003eTraceable via the National Metrology Institute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC extension option\u003c\/td\u003e\n\u003ctd\u003eOption 0DC, DC to 26.5 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration certificate options\u003c\/td\u003e\n\u003ctd\u003eUK6 commercial certificate with test data; 1A7; AJ6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical calibration time\u003c\/td\u003e\n\u003ctd\u003eLess than half the time of a mechanical cal kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003cp\u003eManufacturer information: \u003ca href=\"https:\/\/keysight.com\/es\/en\/product\/N4433D\/rf-electronic-calibration-module-ecal-dc-300khz-26-5ghz-4-ports.html\" target=\"_blank\" rel=\"noopener\"\u003eKeysight N4433D RF Electronic Calibration Module (ECal) — keysight.com\u003c\/a\u003e\u003c\/p\u003e","brand":"Keysight","offers":[{"title":"Default Title","offer_id":67776330039483,"sku":"IMM_UGBLZAQ_EC_085","price":26068.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0777\/2635\/1547\/files\/n4433d-angle-600x600-1.jpg?v=1792552831","url":"https:\/\/indomultimeter.net\/products\/keysight-n4433d-003-010-ecal-module-300-khz-to-26-5-ghz-4-port-3-5-mm","provider":"Indo Multimeter","version":"1.0","type":"link"}