{"product_id":"keysight-e8486a-201-power-sensor-e-band-54-to-95-ghz","title":"Keysight E8486A\/201 Power Sensor, E-Band 54 to 95 GHz","description":"\u003ch2\u003eKeysight E8486A\/201 Power Sensor\u003c\/h2\u003e\n\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThe Keysight E8486A is a diode-sensing waveguide power sensor for E-band average power measurements. Option 201 extends the frequency range beyond the standard 60 to 90 GHz coverage to 54 to 95 GHz, while widening the measurable power range to -60 to +20 dBm (1 nW to 100 mW). Power enters through a UG-387\/U flange on EIA WR-12 waveguide, and a maximum SWR of 1.06 minimizes the mismatch uncertainty that dominates most millimeter-wave power measurements.\u003c\/p\u003e\u003cp\u003eThe sensor incorporates a 50 MHz, 1 mW calibration port so the meter and sensor combination can be referenced before measuring, and it stores calibration factors in EEPROM for automatic correction on compatible power meters. It works with Keysight EPM (E4418B\/19B, N1913A\/14A), EPM-P (E4416A\/17A) and P-Series (N1911A\/12A) power meters as well as the E1416A VXI power meter, giving existing E-band test benches a drop-in, NIST-traceable sensing element.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eE-band coverage from 54 to 95 GHz with option 201\u003c\/li\u003e\n\u003cli\u003eWide -60 to +20 dBm (1 nW to 100 mW) average power range\u003c\/li\u003e\n\u003cli\u003eEIA WR-12 waveguide with UG-387\/U flange connector\u003c\/li\u003e\n\u003cli\u003eMaximum SWR of 1.06 to reduce mismatch uncertainty\u003c\/li\u003e\n\u003cli\u003e50 MHz, 1 mW reference calibration port\u003c\/li\u003e\n\u003cli\u003eEEPROM-stored calibration factors with E-series compatible meters\u003c\/li\u003e\n\u003cli\u003eCompatible with EPM, EPM-P and P-Series power meters\u003c\/li\u003e\n\u003cli\u003eNIST-traceable millimeter-wave sensor calibration\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eE-band link and component average power measurements\u003c\/li\u003e\n\u003cli\u003eMillimeter-wave production test and verification of waveguide assemblies\u003c\/li\u003e\n\u003cli\u003ePower verification for radar, satellite and 5G backhaul research in V\/E bands\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eKeysight E8486A\/201 Power Sensor Technical Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel \/ option\u003c\/td\u003e\n\u003ctd\u003eE8486A with option 201 (E-band extended range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency range\u003c\/td\u003e\n\u003ctd\u003e54 to 95 GHz (option 201); 60 to 90 GHz (options 100\/200)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower range\u003c\/td\u003e\n\u003ctd\u003e-60 to +20 dBm (1 nW to 100 mW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector type\u003c\/td\u003e\n\u003ctd\u003eWaveguide flange UG-387\/U, EIA WR-12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum SWR\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1.06 (\u0026lt; 1.076 at 50 MHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum power\u003c\/td\u003e\n\u003ctd\u003e200 mW average, 40 W peak (10 µs pulse, 0.5% duty cycle)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower linearity\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; ±1.5% (option 200\/201 dynamic range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensing element\u003c\/td\u003e\n\u003ctd\u003eDiode power sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration port\u003c\/td\u003e\n\u003ctd\u003e50 MHz, 1 mW reference output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible power meters\u003c\/td\u003e\n\u003ctd\u003eEPM (E4418B\/19B, N1913A\/14A), EPM-P (E4416A\/17A), P-Series (N1911A\/12A), E1416A VXI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTraceability\u003c\/td\u003e\n\u003ctd\u003eNIST millimeter-wave sensor calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eManufacturer information: \u003ca href=\"https:\/\/www.keysight.com\/us\/en\/product\/E8486A\/waveguide-power-sensor-60-90-ghz.html\" target=\"_blank\" rel=\"noopener\"\u003eKeysight E8486A Waveguide Power Sensor on keysight.com\u003c\/a\u003e\u003c\/p\u003e","brand":"Keysight","offers":[{"title":"Default Title","offer_id":67776157221051,"sku":"IMM_22765323","price":13824.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0777\/2635\/1547\/files\/e8486a_01_1023-600x600-1.jpg?v=1792552066","url":"https:\/\/indomultimeter.net\/products\/keysight-e8486a-201-power-sensor-e-band-54-to-95-ghz","provider":"Indo Multimeter","version":"1.0","type":"link"}