{"product_id":"keysight-e4362a-j06-solar-array-simulator-module-180-v-3-4-a-565-w","title":"Keysight E4362A\/J06 Solar Array Simulator Module, 180 V, 3.4 A, 565 W","description":"\u003ch2\u003eKeysight E4362A\/J06 Solar Array Simulator Module, 180 V, 3.4 A, 565 W\u003c\/h2\u003e\n\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe Keysight E4362A\/J06 is a solar array simulator (SAS) DC power module that plugs into the E4360A Modular Solar Array Simulator mainframe, which accepts up to two modules in a 2U chassis. In the J06 configuration the module is rated for a maximum open-circuit voltage (Voc) of 180 V, a maximum short-circuit current (Isc) of 3.4 A and about 565 W of output power. The instrument behaves chiefly as a current source with very low output capacitance, which lets it follow the sharp knee of a real I-V curve.\u003c\/p\u003e\n\u003cp\u003eYou can define the simulated array either by entering the four key parameters (Voc, Isc, Vmp, Imp) so the module generates the I-V curve internally, or by downloading a user-defined table for the curve. Fast I-V curve changes make it practical to emulate environmental effects such as temperature, aging, eclipse and spin. The E4362A\/J06 provides LAN, USB and GPIB interfaces as standard and is fully compliant with LXI Class C, and the 14360A System Control Tool software shipped with the E4360A mainframe can coordinate up to 100 SAS outputs from a single function call.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eJ06 configuration: 180 V maximum Voc, 3.4 A maximum Isc, 565 W power rating\u003c\/li\u003e\n\u003cli\u003eSimulates solar arrays by four-parameter entry (Voc, Isc, Vmp, Imp) or user-defined I-V tables\u003c\/li\u003e\n\u003cli\u003eFast I-V curve changes and fast recovery switching for dynamic shading and eclipse tests\u003c\/li\u003e\n\u003cli\u003eVery low output capacitance for current-source-like behavior at the curve knee\u003c\/li\u003e\n\u003cli\u003eLAN, USB and GPIB interfaces standard; LXI Class C compliant\u003c\/li\u003e\n\u003cli\u003eWorks in the 2U E4360A mainframe with up to two modules per frame\u003c\/li\u003e\n\u003cli\u003e14360A System Control Tool software supports multi-output SAS system control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTesting maximum power point tracking (MPPT) converters and solar charge controllers\u003c\/li\u003e\n\u003cli\u003eEmulating satellite and spacecraft solar arrays under eclipse, spin and aging conditions\u003c\/li\u003e\n\u003cli\u003eCharacterizing photovoltaic inverters and power conditioning electronics\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKeysight E4362A\/J06 Solar Array Simulator Module, 180 V, 3.4 A, 565 W Technical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput ratings (simulator\/table mode)\u003c\/th\u003e\n\u003ctd\u003eMax. power 600 W; Voc max. 180 V; Isc max. 3.4 A (J06)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput ratings (fixed mode)\u003c\/th\u003e\n\u003ctd\u003eMax. power 600 W; V rated 166.2 V; I rated 3.4 A (220\/240 VAC) or 1.7 A (100\/120 VAC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProgramming accuracy (fixed mode)\u003c\/th\u003e\n\u003ctd\u003eVoltage 0.075% + 20 mV; current 0.2% + 10 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRipple \u0026amp; noise, voltage (simulator\/table mode)\u003c\/th\u003e\n\u003ctd\u003e28 mV rms \/ 249 mV p-p (20 Hz to 20 MHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRipple \u0026amp; noise, voltage (fixed mode)\u003c\/th\u003e\n\u003ctd\u003e35 mV rms \/ 150 mV p-p (20 Hz to 20 MHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRipple \u0026amp; noise, current (fixed mode)\u003c\/th\u003e\n\u003ctd\u003e3 mA rms \/ 20 mA p-p\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard power rating (E4362A base model)\u003c\/th\u003e\n\u003ctd\u003e130 V, 5 A, 600 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInterfaces\u003c\/th\u003e\n\u003ctd\u003eLAN, USB, GPIB (standard)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCompliance\u003c\/th\u003e\n\u003ctd\u003eLXI Class C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMainframe compatibility\u003c\/th\u003e\n\u003ctd\u003eKeysight E4360A Modular SAS mainframe, up to 2 modules, 2U high\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e88.1 mm x 432.5 mm x 633.9 mm (3.5 x 17.03 x 24.96 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutputs\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eManufacturer information: \u003ca href=\"https:\/\/keysight.com\/us\/en\/product\/E4362A\/solar-array-simulator-dc-module-130v-5a-600w.html\" target=\"_blank\" rel=\"noopener\"\u003eKeysight E4362A Solar Array Simulator DC Module product page\u003c\/a\u003e\u003c\/p\u003e","brand":"Keysight","offers":[{"title":"Default Title","offer_id":67776250871995,"sku":"IMM_92355494","price":6525.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0777\/2635\/1547\/files\/e4362_01_0424-600x600-1.jpg?v=1792552330","url":"https:\/\/indomultimeter.net\/products\/keysight-e4362a-j06-solar-array-simulator-module-180-v-3-4-a-565-w","provider":"Indo Multimeter","version":"1.0","type":"link"}