{"product_id":"keithley-6487-picoammeter-voltage-source-5-5-digit-500v-source","title":"Keithley 6487 Picoammeter\/Voltage Source, 5.5 Digit, 500V Source","description":"\u003ch2\u003eKeithley 6487 Picoammeter\/Voltage Source, 5.5 Digit, 500V Source\u003c\/h2\u003e\n\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe Keithley 6487 Picoammeter\/Voltage Source is a 5.5-digit low-current measurement instrument that combines a sensitive feedback picoammeter with a high-resolution 500 V voltage source. It measures currents from 20 fA to 20 mA across eight ranges at speeds up to 1000 readings per second, and its voltage sweep capability automates I-V characterization. Compared with a conventional shunt-type DMM, its feedback design reduces voltage burden by several orders of magnitude to under 200 µV on the lower ranges.\u003c\/p\u003e\n\u003cp\u003eThe instrument supports both the Source Voltage\/Measure Current method for resistances up to 5×10^14 Ω and the Alternating Voltage method, which extends measurement up to 10^16 Ω and improves results on high-noise devices. A time-stamped 3000-reading buffer stores minimum, maximum and standard-deviation statistics, and a Model 487 emulation mode lets existing 487 control code run unchanged. Rear-panel triax input permits floating measurements up to 500 V.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEight current ranges from 20 fA to 20 mA with 10 fA resolution\u003c\/li\u003e\n\u003cli\u003eBuilt-in 500 V voltage source, 200 µV to 505 V\u003c\/li\u003e\n\u003cli\u003e\u0026lt;200 µV voltage burden on the lower ranges\u003c\/li\u003e\n\u003cli\u003eMeasurement speeds up to 1000 readings per second\u003c\/li\u003e\n\u003cli\u003eVoltage sweeps and Alternating Voltage resistance measurements to 10^16 Ω\u003c\/li\u003e\n\u003cli\u003e3000-reading time-stamped buffer with statistics\u003c\/li\u003e\n\u003cli\u003eIEEE-488 and RS-232 interfaces, analog output and digital I\/O\u003c\/li\u003e\n\u003cli\u003eModel 486\/487 emulation mode and Trigger Link interface\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWafer-level photodiode and optoelectronic device testing\u003c\/li\u003e\n\u003cli\u003eHigh-resistance and dark-current characterization of semiconductors\u003c\/li\u003e\n\u003cli\u003eProduction and lab low-current measurements such as leakages and radiation dosimetry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKeithley 6487 Picoammeter\/Voltage Source, 5.5 Digit, 500V Source Technical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCurrent measurement range\u003c\/th\u003e\n\u003ctd\u003e20 fA to 20 mA, 8 ranges\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResolution\u003c\/th\u003e\n\u003ctd\u003e10 fA (5.5 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage burden\u003c\/th\u003e\n\u003ctd\u003e\u0026lt;200 µV (1 mV on the 20 mA range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage source\u003c\/th\u003e\n\u003ctd\u003e200 µV to 505 V, 0.2 mV best resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReading rate\u003c\/th\u003e\n\u003ctd\u003eUp to 1000 readings\/second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResistance (V\/I method)\u003c\/th\u003e\n\u003ctd\u003eOptimized from 50 Ω to 5×10^14 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAlternating Voltage method\u003c\/th\u003e\n\u003ctd\u003e10^9 Ω to 10^15 Ω, alternating 0 V and up to ±505 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage sweeps\u003c\/th\u003e\n\u003ctd\u003eLinear sweeps, up to 200 steps\/s, max 3000 steps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eData buffer\u003c\/th\u003e\n\u003ctd\u003e3000 time-stamped readings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFloating operation\u003c\/th\u003e\n\u003ctd\u003eUp to 500 V via rear-panel triax input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInterfaces\u003c\/th\u003e\n\u003ctd\u003eIEEE-488, RS-232, Trigger Link, analog output, digital I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEmulation\u003c\/th\u003e\n\u003ctd\u003eModel 486 and Model 487 modes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eManufacturer information: \u003ca href=\"https:\/\/www.tek.com\/en\/products\/keithley\/digital-multimeters\/6487\" target=\"_blank\" rel=\"noopener\"\u003eKeithley 6487 Picoammeter\/Voltage Source product page\u003c\/a\u003e\u003c\/p\u003e","brand":"Keithley","offers":[{"title":"Default Title","offer_id":67776260309179,"sku":"IMM_29639673","price":4223.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0777\/2635\/1547\/files\/6487_01_0724-600x600-1.jpg?v=1792552379","url":"https:\/\/indomultimeter.net\/products\/keithley-6487-picoammeter-voltage-source-5-5-digit-500v-source","provider":"Indo Multimeter","version":"1.0","type":"link"}