Key specs from the product description

Current measurement range
20 fA to 20 mA, 8 ranges
Resolution
10 fA (5.5 digit)
Voltage burden
<200 µV (1 mV on the 20 mA range)
Voltage source
200 µV to 505 V, 0.2 mV best resolution
Reading rate
Up to 1000 readings/second
Resistance (V/I method)
Optimized from 50 Ω to 5×10^14 Ω
All 12 specifications ↓
Keithley 6487 Picoammeter/Voltage Source, 5.5 Digit, 500V Source Overview The Keithley 6487 Picoammeter/Voltage Source is a 5.5-digit low-current measurement instrument that combines a sensitive feedback picoammeter with a...

Need a formal quote or a volume price?

For purchase orders, proforma invoices or several units. We typically reply within one working day.

Available to orderWe ship worldwide Typical response within one working day. The quote confirms the model, price and availability.
Add company, phone or a note
  • Typical reply: one working day
  • Proforma invoice on request
  • Pay by card or bank transfer
  • 30-day money-back on defects
We ship worldwide · Prices in USD
  1. 1Send the requestTakes a minute
  2. 2Get your priceTypically one working day
  3. 3Pay, we shipCard or bank transfer
  • 30-day money-back if the item arrives defective, damaged or wrong. Policy
  • Traceable calibration documentation ships with instruments
  • Pay by card or bank transfer, invoice on request
  • We ship worldwide. Destination confirmed with your quote

Datasheets & manuals

Need the datasheet? Add the request to your quote. Ask for the datasheet
Manufacturer pages
ShippingWe ship worldwide
DocumentsTraceable calibration documentation
Quote responseTypically within one working day

Keithley 6487 Picoammeter/Voltage Source, 5.5 Digit, 500V Source

Overview

The Keithley 6487 Picoammeter/Voltage Source is a 5.5-digit low-current measurement instrument that combines a sensitive feedback picoammeter with a high-resolution 500 V voltage source. It measures currents from 20 fA to 20 mA across eight ranges at speeds up to 1000 readings per second, and its voltage sweep capability automates I-V characterization. Compared with a conventional shunt-type DMM, its feedback design reduces voltage burden by several orders of magnitude to under 200 µV on the lower ranges.

The instrument supports both the Source Voltage/Measure Current method for resistances up to 5×10^14 Ω and the Alternating Voltage method, which extends measurement up to 10^16 Ω and improves results on high-noise devices. A time-stamped 3000-reading buffer stores minimum, maximum and standard-deviation statistics, and a Model 487 emulation mode lets existing 487 control code run unchanged. Rear-panel triax input permits floating measurements up to 500 V.

Features

  • Eight current ranges from 20 fA to 20 mA with 10 fA resolution
  • Built-in 500 V voltage source, 200 µV to 505 V
  • <200 µV voltage burden on the lower ranges
  • Measurement speeds up to 1000 readings per second
  • Voltage sweeps and Alternating Voltage resistance measurements to 10^16 Ω
  • 3000-reading time-stamped buffer with statistics
  • IEEE-488 and RS-232 interfaces, analog output and digital I/O
  • Model 486/487 emulation mode and Trigger Link interface

Applications

  • Wafer-level photodiode and optoelectronic device testing
  • High-resistance and dark-current characterization of semiconductors
  • Production and lab low-current measurements such as leakages and radiation dosimetry

Keithley 6487 Picoammeter/Voltage Source, 5.5 Digit, 500V Source Technical Specifications

Current measurement range 20 fA to 20 mA, 8 ranges
Resolution 10 fA (5.5 digit)
Voltage burden <200 µV (1 mV on the 20 mA range)
Voltage source 200 µV to 505 V, 0.2 mV best resolution
Reading rate Up to 1000 readings/second
Resistance (V/I method) Optimized from 50 Ω to 5×10^14 Ω
Alternating Voltage method 10^9 Ω to 10^15 Ω, alternating 0 V and up to ±505 V
Voltage sweeps Linear sweeps, up to 200 steps/s, max 3000 steps
Data buffer 3000 time-stamped readings
Floating operation Up to 500 V via rear-panel triax input
Interfaces IEEE-488, RS-232, Trigger Link, analog output, digital I/O
Emulation Model 486 and Model 487 modes

Manufacturer information: Keithley 6487 Picoammeter/Voltage Source product page

Price $4,223.00 USD as listed on 25 Nov 2026. Request a firm quote: https://indomultimeter.net/products/keithley-6487-picoammeter-voltage-source-5-5-digit-500v-source

Before you order

Is the price final?

The price shown is our current price in USD. Your quote confirms price and availability for your quantity.

How is my item supplied?

Items are ordered from the manufacturer for you. The quote confirms availability. Typical response is within one working day.

Do you provide calibration certificates?

Instruments ship with calibration documentation traceable to national standards. Ask in your request if you need a specific certificate.

How can I pay?

By card or by bank transfer. We can send a proforma invoice for your purchasing department.

Do you ship to my country?

We ship worldwide. Put your destination country in your enquiry and we confirm delivery with your quote.

What if it arrives defective, damaged or wrong?

You get a 30-day money-back guarantee for items that arrive defective, damaged or wrong. See the refund policy.