{"product_id":"keithley-2000-e-bench-multimeter-6-5-digit-european-version","title":"Keithley 2000\/E Bench Multimeter, 6.5-Digit, European Version","description":"\u003ch2\u003eKeithley 2000\/E Bench Multimeter, 6.5-Digit, European Version\u003c\/h2\u003e\n\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe Keithley 2000\/E is the European power-line version of the Keithley Model 2000, a 6½-digit bench\/system digital multimeter built on the same high-speed, low-noise A\/D converter technology used in the 7½- and 8½-digit Models 2001 and 2002. The \/E configuration is supplied for 220 V European mains operation. It measures DC voltage from 100 nV to 1 kV with 0.002% 90-day basic accuracy and DC resistance from 100 μΩ to 100 MΩ with 0.008% 90-day basic accuracy, and it offers 13 built-in functions including DCV, ACV, DCI, ACI, 2-wire and 4-wire ohms, temperature, frequency, period, dB, dBm, continuity and diode test.\u003c\/p\u003e\n\u003cp\u003eFor system use, the Model 2000 delivers 50 triggered readings\/second over the IEEE-488 bus at 6½ digits and up to 2000 readings\/second into its internal 1024-reading buffer at 4½ digits. Programming is available in SCPI, the Keithley 196\/199 command set or the Fluke 8840A\/8842A command set, and a rear-panel card slot accepts optional scanner cards for multipoint measurement. Up to 1024 readings and two setups can be stored and recalled from the front panel.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e6½-digit resolution with 100 nV DC voltage sensitivity\u003c\/li\u003e\n\u003cli\u003e0.002% 90-day basic DCV accuracy and 0.008% 90-day basic resistance accuracy\u003c\/li\u003e\n\u003cli\u003e13 built-in measurement functions including temperature (thermocouple) inputs\u003c\/li\u003e\n\u003cli\u003e2000 readings\/second at 4½ digits into a 1024-reading internal buffer\u003c\/li\u003e\n\u003cli\u003eIEEE-488 (GPIB) and RS-232 interfaces standard\u003c\/li\u003e\n\u003cli\u003eSCPI plus Keithley 196\/199 and Fluke 8840A\/8842A command sets\u003c\/li\u003e\n\u003cli\u003eRear-panel slot for optional multiplexer\/scanner cards for multipoint testing\u003c\/li\u003e\n\u003cli\u003eEuropean 220 V mains configuration (\/E version)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBench and rack verification of precision voltage, current and resistance references in European labs\u003c\/li\u003e\n\u003cli\u003eMultipoint automated test systems with scanner cards over GPIB\/RS-232\u003c\/li\u003e\n\u003cli\u003eProduction test of components and modules requiring 6½-digit throughput\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKeithley 2000\/E Bench Multimeter, 6.5-Digit, European Version Technical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e2000\/E (Model 2000, European version)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e6½ digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC voltage range \/ accuracy\u003c\/td\u003e\n\u003ctd\u003e100 nV to 1 kV; 0.002% 90-day basic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC resistance range \/ accuracy\u003c\/td\u003e\n\u003ctd\u003e100 μΩ to 100 MΩ; 0.008% 90-day basic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctions\u003c\/td\u003e\n\u003ctd\u003eDCV, ACV, DCI, ACI, 2W\/4W ohms, temperature, frequency, period, dB, dBm, continuity, diode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax AC voltage \/ current\u003c\/td\u003e\n\u003ctd\u003e750 V AC \/ 3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading rate\u003c\/td\u003e\n\u003ctd\u003e50 rdgs\/s @ 6½ digits (GPIB); 2000 rdgs\/s @ 4½ digits (buffer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading buffer\u003c\/td\u003e\n\u003ctd\u003e1024 readings, 2 stored setups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterfaces\u003c\/td\u003e\n\u003ctd\u003eIEEE-488 (GPIB), RS-232C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgramming\u003c\/td\u003e\n\u003ctd\u003eSCPI, Keithley 196\/199, Fluke 8840A\/8842A command sets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency counter range\u003c\/td\u003e\n\u003ctd\u003e3 Hz to 500 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature range\u003c\/td\u003e\n\u003ctd\u003e-100°C to +630°C (thermocouple input)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions \/ weight\u003c\/td\u003e\n\u003ctd\u003e89 x 213 x 370 mm; 2.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMains\u003c\/td\u003e\n\u003ctd\u003e220 V AC (European \/E configuration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003cp\u003eManufacturer information: \u003ca href=\"https:\/\/download.tek.com\/manual\/2000-900_J-Aug2010_User.pdf\" target=\"_blank\" rel=\"noopener\"\u003eKeithley Model 2000 Multimeter (Tektronix)\u003c\/a\u003e\u003c\/p\u003e","brand":"Keithley","offers":[{"title":"Default Title","offer_id":67776224526523,"sku":"IMM_99736863","price":669.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0777\/2635\/1547\/files\/keithley-2000-e-600x600-1.jpg?v=1792552166","url":"https:\/\/indomultimeter.net\/products\/keithley-2000-e-bench-multimeter-6-5-digit-european-version","provider":"Indo Multimeter","version":"1.0","type":"link"}