Key specs from the product description

Nominal resistance
100 Ohm at 0 °C
Temperature coefficient
0.003923 Ohm/Ohm/°C nominal
Temperature range
-200 °C to 500 °C
Calibrated accuracy (k=2)
+/-0.026 °C at -200 °C; +/-0.066 °C at 0 °C; +/-0.219 °C at 500 °C
Drift rate
+/-0.1 °C when used periodically to 500 °C
Hysteresis
Less than 0.01 °C at 0 °C
All 12 specifications ↓
Fluke Calibration 5618B-12-D Temperature ProbeOverviewThe Fluke Calibration 5618B-12-D Temperature Probe is a secondary-level industrial platinum resistance thermometer (PRT) built around a 100 Ohm sensor with a 3.2 mm...

Need a formal quote or a volume price?

For purchase orders, proforma invoices or several units. We typically reply within one working day.

Available to orderWe ship worldwide Typical response within one working day. The quote confirms the model, price and availability.
Add company, phone or a note
  • Typical reply: one working day
  • Proforma invoice on request
  • Pay by card or bank transfer
  • 30-day money-back on defects
We ship worldwide · Prices in USD
  1. 1Send the requestTakes a minute
  2. 2Get your priceTypically one working day
  3. 3Pay, we shipCard or bank transfer
  • 30-day money-back if the item arrives defective, damaged or wrong. Policy
  • Traceable calibration documentation ships with instruments
  • Pay by card or bank transfer, invoice on request
  • We ship worldwide. Destination confirmed with your quote

Datasheets & manuals

Need the datasheet? Add the request to your quote. Ask for the datasheet
Manufacturer pages
ShippingWe ship worldwide
DocumentsTraceable calibration documentation
Quote responseTypically within one working day

Fluke Calibration 5618B-12-D Temperature Probe

Overview

The Fluke Calibration 5618B-12-D Temperature Probe is a secondary-level industrial platinum resistance thermometer (PRT) built around a 100 Ohm sensor with a 3.2 mm (1/8 in) diameter sheath. The slim sheath shortens response time while retaining precision, and the probe is supplied with a full accredited calibration report containing test data and ITS-90 coefficients that can be entered directly into a Fluke Calibration thermometer readout.

The 12-inch (305 mm) model operates from -200 °C to 500 °C, and Fluke recommends pairing it with the 1523, 1524, 1502A, 1529 or 1560 thermometer readouts. Because it delivers reference-grade performance in an industrial form factor, the 5618B is also used to calibrate Fluke Calibration 9132 and 9133 infrared calibrators in-house. The D termination is a 5-pin DIN connector for Tweener thermometers.

Features

  • Secondary-level performance with full ITS-90 calibration and accredited report
  • 3.2 mm (1/8 in) diameter sheath for fast response in tight insertion points
  • Temperature range -200 °C to 500 °C on the 12-inch model
  • 5-pin DIN termination for Tweener thermometers
  • Reduced heat conduction for lower measurement error at short immersion depths
  • 316 stainless steel sheath with 22 AWG PTFE leads, 6 ft long
  • Suitable for calibrating Fluke 9132 and 9133 infrared calibrators

Applications

  • Critical process temperature measurements in plants and pilot facilities
  • Calibration of infrared calibrator blackbody targets in working labs
  • Reference probing with Fluke 1523, 1524, 1502A, 1529 and 1560 readouts

Fluke Calibration 5618B-12-D Temperature Probe Technical Specifications

Nominal resistance 100 Ohm at 0 °C
Temperature coefficient 0.003923 Ohm/Ohm/°C nominal
Temperature range -200 °C to 500 °C
Calibrated accuracy (k=2) +/-0.026 °C at -200 °C; +/-0.066 °C at 0 °C; +/-0.219 °C at 500 °C
Drift rate +/-0.1 °C when used periodically to 500 °C
Hysteresis Less than 0.01 °C at 0 °C
Time constant 4 seconds maximum for 63.2% response in water moving at 3 fps
Sheath material 316 stainless steel
Sheath size 305 mm x 3.2 mm (12 in x 1/8 in)
Leads 22 AWG PTFE, 6 ft
Termination D: 5-pin DIN for Tweener thermometers
Calibration included Manufacturer's accredited calibration with ITS-90 coefficients, R vs T values in 1 °C increments

Manufacturer information: Fluke 5618B product page

Price $772.00 USD as listed on 26 Nov 2026. Request a firm quote: https://indomultimeter.net/products/fluke-calibration-5618b-12-d-temperature-probe-305-mm-small-diameter-industrial-rtd-5-pin-din

Before you order

Is the price final?

The price shown is our current price in USD. Your quote confirms price and availability for your quantity.

How is my item supplied?

Items are ordered from the manufacturer for you. The quote confirms availability. Typical response is within one working day.

Do you provide calibration certificates?

Instruments ship with calibration documentation traceable to national standards. Ask in your request if you need a specific certificate.

How can I pay?

By card or by bank transfer. We can send a proforma invoice for your purchasing department.

Do you ship to my country?

We ship worldwide. Put your destination country in your enquiry and we confirm delivery with your quote.

What if it arrives defective, damaged or wrong?

You get a 30-day money-back guarantee for items that arrive defective, damaged or wrong. See the refund policy.