{"product_id":"fluke-771-milliamp-process-clamp-meter-0-2-accuracy-99-9-ma-range","title":"Fluke 771 Milliamp Process Clamp Meter, 0.2% Accuracy, 99.9 mA Range","description":"\u003ch2\u003eFluke 771 Milliamp Process Clamp Meter, 0.2% Accuracy, 99.9 mA Range\u003c\/h2\u003e\n\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 771 Milliamp Process Clamp Meter is a specialized clamp meter for troubleshooting analog input and output loops in PLC and distributed control systems. Its clamp pickup senses 4 to 20 mA transmitter output signals without disconnecting the loop, so control signals can be checked on live installations. The 99.9 mA range extends its use to older control systems that still carry 10 to 50 mA signals.\u003c\/p\u003e\n\u003cp\u003eThe dual backlit display shows the current reading in milliamps and, simultaneously, the value as a percentage of the 4 to 20 mA span, which speeds fault isolation. A Hold function captures changing measurements, and the built-in Measurement Spotlight illuminates wiring in dark cabinets. The clamp detaches from the body via an extension cable for measurements in cramped spaces.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMeasures 4 to 20 mA transmitter signals without breaking the loop\u003c\/li\u003e\n\u003cli\u003e0.2% of reading + 5 counts accuracy, resolution and sensitivity to 0.01 mA\u003c\/li\u003e\n\u003cli\u003eDual backlit display with mA reading and % of 4-20 mA span\u003c\/li\u003e\n\u003cli\u003eMeasurement Spotlight for wiring in dark enclosures\u003c\/li\u003e\n\u003cli\u003eDetachable clamp with extension cable for tight locations\u003c\/li\u003e\n\u003cli\u003e99.9 mA range for 10 to 50 mA legacy control signals\u003c\/li\u003e\n\u003cli\u003eZero and Hold functions; automatic battery-saving shutdowns\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCommissioning and troubleshooting PLC analog I\/O loops\u003c\/li\u003e\n\u003cli\u003eChecking 4-20 mA transmitter output signals in process plants\u003c\/li\u003e\n\u003cli\u003eVerifying 10 to 50 mA signals in older control systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat's in the Box\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSoft carrying case\u003c\/li\u003e\n\u003cli\u003eUser's manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFluke 771 Milliamp Process Clamp Meter, 0.2% Accuracy, 99.9 mA Range Technical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003ctd\u003e-20.99 to +20.99 mA and ±21.0 to 99.9 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003ctd\u003e0.2% of reading + 5 counts (main range); 1% + 5 counts (99.9 mA range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResolution\u003c\/th\u003e\n\u003ctd\u003e0.01 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax conductor diameter\u003c\/th\u003e\n\u003ctd\u003e4.5 mm (0.177 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e-10°C to 55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-25°C to 70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHumidity\u003c\/th\u003e\n\u003ctd\u003e\u0026lt;95% @ \u0026lt;30°C; \u0026lt;75% @ 30°C to 55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIP rating\u003c\/th\u003e\n\u003ctd\u003eIP 40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e59 x 38 x 212 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e260 g (9.1 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower\u003c\/th\u003e\n\u003ctd\u003e2 x AA 1.5 V alkaline, approx. 40 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety\/EMC\u003c\/th\u003e\n\u003ctd\u003eMeets EN61326-1; 1 m drop test (except jaw)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 years electronics, 1 year clamp cable assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eManufacturer information: \u003ca href=\"https:\/\/www.fluke.com\/en-us\/product\/calibration-tools\/ma-loop-calibrators\/fluke-771\" target=\"_blank\" rel=\"noopener\"\u003eFluke 771 Milliamp Clamp Meter product page\u003c\/a\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":67776259424443,"sku":"IMM_45388974","price":381.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0777\/2635\/1547\/files\/fluke-771-600x600-1.jpg?v=1792552375","url":"https:\/\/indomultimeter.net\/products\/fluke-771-milliamp-process-clamp-meter-0-2-accuracy-99-9-ma-range","provider":"Indo Multimeter","version":"1.0","type":"link"}