{"product_id":"emerson-trexlfpna9s3-field-communicator","title":"Emerson TREXLFPNA9S3 Field Communicator","description":"\u003ch2\u003eEmerson TREXLFPNA9S3 Field Communicator\u003c\/h2\u003e\n\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThe Emerson TREXLFPNA9S3 Field Communicator is a configuration of the AMS Trex Device Communicator, decoded from its model number: L for the Device Communicator Plus communication module, F for HART and FOUNDATION Fieldbus applications, P for the rechargeable Li-Ion power module, NA for no approval rating, 9 for no radio option and S3 for three years of Standard Support with technical support and software updates. The Plus module adds a HART + power terminal with a built-in HART power supply, 167 Ohm resistors, current control and an ammeter, and an mA terminal that measures 4-20 mA loops with 0.1 mA resolution; the FF + power terminal can power one Foundation Fieldbus device on the bench.\u003c\/p\u003e\u003cp\u003eTrex communicators are built for one-handed, all-day field use in a balanced form factor with a rugged hand strap and IP54 enclosure that survives a 1-meter drop onto concrete. The 5.7 inch (14.5 cm) 640 x 480 color VGA resistive touchscreen works with gloved hands and adjusts for sunlight or dark environments. Under the hood sit an 800 MHz ARM Cortex A8 processor, 512 MB DDR3 RAM and 32 GB of application storage running Windows Embedded Compact 2013, with an 8+ hour Li-Ion battery that can also power connected field devices. Device interoperability is achieved through EDDL technology, and field changes synchronize automatically with the AMS Device Manager database via USB; ValveLink Mobile is available at no charge once the unit is activated.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDevice Communicator Plus module with HART + power, mA and FF + power terminals\u003c\/li\u003e\n\u003cli\u003eHART and FOUNDATION Fieldbus applications included (Foundation Fieldbus power plug included)\u003c\/li\u003e\n\u003cli\u003ePower the Loop functionality drives devices directly from the communicator\u003c\/li\u003e\n\u003cli\u003eLoop and Fieldbus Diagnostics apps for troubleshooting and segment validation\u003c\/li\u003e\n\u003cli\u003e5.7 in 640 x 480 color VGA resistive touchscreen, glove friendly\u003c\/li\u003e\n\u003cli\u003eRechargeable Li-Ion power module, 8+ hours typical operation\u003c\/li\u003e\n\u003cli\u003eIP54 enclosure, 1 m drop-tested, intrinsically safe design (this variant: no approval)\u003c\/li\u003e\n\u003cli\u003e32 GB memory, USB connectivity, automatic AMS Device Manager sync, 3-year Standard Support\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eConfiguring and troubleshooting HART and Foundation Fieldbus transmitters and valves in the field\u003c\/li\u003e\n\u003cli\u003eInline valve testing and commissioning with ValveLink Mobile for Fisher FIELDVUE controllers\u003c\/li\u003e\n\u003cli\u003eLoop power-up, checkout and diagnostics before plant I\/O infrastructure is complete\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eEmerson TREXLFPNA9S3 Field Communicator Technical Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel code\u003c\/td\u003e\n\u003ctd\u003eTREX L F P NA 9 S3 (Device Communicator Plus, HART+FF, Li-Ion, no approval, no radio, 3-yr support)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor\u003c\/td\u003e\n\u003ctd\u003e800 MHz ARM Cortex A8 (NXP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003e2 GB NAND internal flash, 32 GB extended flash, 512 MB DDR3 RAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating system\u003c\/td\u003e\n\u003ctd\u003eWindows Embedded Compact 2013\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e5.7 in (14.5 cm) color VGA resistive touchscreen, 640 x 480\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHART terminal\u003c\/td\u003e\n\u003ctd\u003eBanana jacks, optional 250 or 500 Ohm internal resistor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHART + power terminal\u003c\/td\u003e\n\u003ctd\u003eHART supply, 167 Ohm resistors, current control, ammeter, 3-22.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emA terminal\u003c\/td\u003e\n\u003ctd\u003eExternal ammeter, up to 22.5 mA, 0.1 mA resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFF + power terminal\u003c\/td\u003e\n\u003ctd\u003eFoundation Fieldbus power conditioner, 0-38 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003eRechargeable Li-Ion power module, 8+ hours typical use, 3-4 h charge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e-20°C to +55°C (-4°F to 131°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure rating\u003c\/td\u003e\n\u003ctd\u003eIP54; survives 1 m drop onto concrete\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 1.33 kg (2.9 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eManufacturer information: \u003ca href=\"https:\/\/www.emerson.com\/en-us\/automation\/trex-device-communicator\" target=\"_blank\" rel=\"noopener\"\u003eEmerson AMS Trex Device Communicator product page\u003c\/a\u003e\u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":67776352223419,"sku":"IMM_46524718","price":5656.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0777\/2635\/1547\/files\/emerson1-600x600-1-4.jpg?v=1792552955","url":"https:\/\/indomultimeter.net\/products\/emerson-trexlfpna9s3-field-communicator","provider":"Indo Multimeter","version":"1.0","type":"link"}