{"product_id":"dwyer-instruments-ds-400-20-duct-flow-sensor-averaging-pitot-in-line-flow-sensor-for-20-inch-pipe","title":"Dwyer Instruments DS-400-20 Duct Flow Sensor, Averaging Pitot In-Line Flow Sensor for 20-Inch Pipe","description":"\u003ch2\u003eDwyer Instruments DS-400-20 Duct Flow Sensor\u003c\/h2\u003e\n\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe Series DS-400 in-line flow sensors are averaging pitot tubes for compatible gases and liquids in Schedule 40 pipe. Multiple sensing ports and built-in averaging eliminate the need to traverse the flowing stream with single-point velocity pressure measurement, and the extra-strong 3\/4-inch diameter stainless steel tube resists the increased forces encountered at higher flow rates with both air and water.\u003c\/p\u003e\n\u003cp\u003eThe sensor includes quick-acting quarter-turn ball valves on both pressure connections for isolation and zeroing, with 1\/8-inch female NPT valve connections rated at 200 psig and 200 °F. A pair of 1\/8 NPT x 1\/4 SAE 45° flared adapters and a solid brass mounting adapter with 3\/4-inch compression fitting and 3\/4-inch male NPT thread are supplied for mounting in a threaded branch connection.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAveraging pitot tube design with multiple sensing points\u003c\/li\u003e\n\u003cli\u003eSized for 20-inch Schedule 40 pipe\u003c\/li\u003e\n\u003cli\u003eExtra-strong 3\/4-inch diameter stainless steel tube\u003c\/li\u003e\n\u003cli\u003eQuarter-turn ball valves isolate the sensor for zeroing\u003c\/li\u003e\n\u003cli\u003e1\/8-inch female NPT valve connections rated 200 psig at 200 °F\u003c\/li\u003e\n\u003cli\u003eIncludes pair of 1\/8 NPT x 1\/4 SAE 45° flared adapters\u003c\/li\u003e\n\u003cli\u003eSolid brass mounting adapter with 3\/4-inch compression fitting\u003c\/li\u003e\n\u003cli\u003eEconomical flow indication with a Capsuhelic differential pressure gage\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAir, gas and liquid flow monitoring in large ducts and pipelines\u003c\/li\u003e\n\u003cli\u003eBoiler feedwater, cooling water and steam flow indication\u003c\/li\u003e\n\u003cli\u003eCombustion air, flue and stack gas flow measurement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat's in the Box\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDS-400-20 averaging flow sensor with quarter-turn isolation valves\u003c\/li\u003e\n\u003cli\u003ePair of 1\/8 NPT x 1\/4 SAE 45° flared adapters\u003c\/li\u003e\n\u003cli\u003eSolid brass mounting adapter with 3\/4-inch compression fitting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDwyer Instruments DS-400-20 Duct Flow Sensor Technical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eAveraging pitot tube in-line flow sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePipe size\u003c\/th\u003e\n\u003ctd\u003e20-inch Schedule 40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensor tube\u003c\/th\u003e\n\u003ctd\u003e3\/4-inch diameter 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eService\u003c\/th\u003e\n\u003ctd\u003eCompatible gases and liquids\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature limit\u003c\/th\u003e\n\u003ctd\u003e200 °F (93.3 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePressure limit\u003c\/th\u003e\n\u003ctd\u003e200 psig (13.7 bar) at 200 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProcess connection\u003c\/th\u003e\n\u003ctd\u003e3\/4-inch male NPT compression fitting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePiping connection\u003c\/th\u003e\n\u003ctd\u003e1\/8-inch female NPT with 1\/8 NPT x 1\/4 SAE 45° flared adapters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIsolation valves\u003c\/th\u003e\n\u003ctd\u003eQuarter-turn ball valves on both pressure connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCompression fitting\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003eManufacturer information: \u003ca href=\"https:\/\/www.dwyeromega.com\/en-us\/averaging-pitot-tube-flow-sensors-for-gases-liquids-1-10-in-pipes\/p\/Series-DS\" target=\"_blank\" rel=\"noopener\"\u003eSeries DS in-line flow sensors on dwyeromega.com\u003c\/a\u003e.\u003c\/p\u003e","brand":"Dwyer Instruments","offers":[{"title":"Default Title","offer_id":67777077805243,"sku":"IMM_79821586","price":439.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0777\/2635\/1547\/files\/dwyer-instruments-ds-400-20.jpg?v=1792556520","url":"https:\/\/indomultimeter.net\/products\/dwyer-instruments-ds-400-20-duct-flow-sensor-averaging-pitot-in-line-flow-sensor-for-20-inch-pipe","provider":"Indo Multimeter","version":"1.0","type":"link"}