Key specs from the product description

Pressure modules
2 x 1,000 psi gauge
Module accuracy
0-30% of range: +/- (0.015% of FS); 30-110%: +/- 0.05% of reading
Differential mode uncertainty
The greater of 0.02 psi or 0.05% of DP reading (with tare)
Wetted materials
316 stainless steel, Viton o-ring
Display
255 x 160 pixel graphical LCD, backlight
Display rate
4 readings/s standard, up to 10/s recording
All 13 specifications ↓
Crystal NV-4AA-1KPSI-1KPSI Reference RecorderOverview The nVision chassis logs up to 1,000,000 data points to non-volatile flash at intervals from 10 readings per second to 1 per hour, and...

Need a formal quote or a volume price?

For purchase orders, proforma invoices or several units. We typically reply within one working day.

Available to orderWe ship worldwide Typical response within one working day. The quote confirms the model, price and availability.
Add company, phone or a note
  • Typical reply: one working day
  • Proforma invoice on request
  • Pay by card or bank transfer
  • 30-day money-back on defects
We ship worldwide · Prices in USD
  1. 1Send the requestTakes a minute
  2. 2Get your priceTypically one working day
  3. 3Pay, we shipCard or bank transfer
  • 30-day money-back if the item arrives defective, damaged or wrong. Policy
  • Traceable calibration documentation ships with instruments
  • Pay by card or bank transfer, invoice on request
  • We ship worldwide. Destination confirmed with your quote

Datasheets & manuals

ShippingWe ship worldwide
DocumentsTraceable calibration documentation
Quote responseTypically within one working day

Crystal NV-4AA-1KPSI-1KPSI Reference Recorder

Overview

The nVision chassis logs up to 1,000,000 data points to non-volatile flash at intervals from 10 readings per second to 1 per hour, and exports CSV, XLS or signed PDF files through CrystalControl software. With tare enabled in CrystalControl, the two identical-range modules support differential pressure measurement with 0.02 psi or 0.05% of reading uncertainty.

The IP66/IP67 housing is submersible to 1 m for 30 minutes, runs about 200 hours on 4 AA batteries (up to 60 days in ultra-low-power recording) and is ATEX/IECEx and CSA intrinsically safe approved. Standard delivery includes an ISO 17025 accredited, NIST traceable calibration certificate, soft carrying case, protective boot and mini-USB cable.

Features

  • Two 1,000 psi pressure modules in one recorder
  • Module accuracy +/- (0.015% FS) 0-30% and +/- 0.05% of reading 30-110% of range
  • Differential pressure with tare: 0.02 psi or 0.05% of reading
  • Datalogging up to 1,000,000 points, 10 readings/s to 1/hour
  • 255 x 160 pixel graphical LCD, 4 to 10 readings per second
  • IP66/IP67, submersible to 1 m for 30 minutes
  • ATEX/IECEx and CSA intrinsically safe certifications
  • USB interface with CrystalControl software

Applications

  • Differential pressure transmitter calibration
  • Pressure gauge and switch field verification
  • Process monitoring and recording in hazardous areas

What's in the Box

  • nVision recorder with two 1KPSI modules
  • 4 AA battery module
  • Soft carrying case (P/N 6053)
  • Protective boot (P/N 3985)
  • Mini-USB cable (P/N 3951)
  • ISO 17025 accredited calibration certificate

Crystal NV-4AA-1KPSI-1KPSI Reference Recorder Technical Specifications

Pressure modules 2 x 1,000 psi gauge
Module accuracy 0-30% of range: +/- (0.015% of FS); 30-110%: +/- 0.05% of reading
Differential mode uncertainty The greater of 0.02 psi or 0.05% of DP reading (with tare)
Wetted materials 316 stainless steel, Viton o-ring
Display 255 x 160 pixel graphical LCD, backlight
Display rate 4 readings/s standard, up to 10/s recording
Datalogging About 1,000,000 points, non-volatile flash
Logging interval 10 per second to 1 per hour
Interface Mini-USB, CrystalControl software
Power 4 x AA alkaline, about 200 hours typical
Operating temperature -20 to 50 degrees C
Enclosure IP66/IP67, 680 g with modules
Certifications ATEX/IECEx Ex ia IIB T4/T3 Ga, CSA Class I Div 1

Manufacturer information: nVision psi datasheet on ametekcalibration.com.

Price $3,035.00 USD as listed on 26 Nov 2026. Request a firm quote: https://indomultimeter.net/products/crystal-nv-4aa-1kpsi-1kpsi-reference-recorder-two-1000-psi-modules-portable

Before you order

Is the price final?

The price shown is our current price in USD. Your quote confirms price and availability for your quantity.

How is my item supplied?

Items are ordered from the manufacturer for you. The quote confirms availability. Typical response is within one working day.

Do you provide calibration certificates?

Instruments ship with calibration documentation traceable to national standards. Ask in your request if you need a specific certificate.

How can I pay?

By card or by bank transfer. We can send a proforma invoice for your purchasing department.

Do you ship to my country?

We ship worldwide. Put your destination country in your enquiry and we confirm delivery with your quote.

What if it arrives defective, damaged or wrong?

You get a 30-day money-back guarantee for items that arrive defective, damaged or wrong. See the refund policy.