{"product_id":"crystal-engineering-hpc42-1kpsi-3kpsi-chx-pump-system-dual-1000-3000-psi-sensors-with-t-620h-pump","title":"Crystal Engineering HPC42-1KPSI-3KPSI-CHX Pump System, Dual 1,000\/3,000 psi Sensors with T-620H Pump","description":"\u003ch2\u003eCrystal Engineering HPC42-1KPSI-3KPSI-CHX Pump System\u003c\/h2\u003e\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eTwo isolated sensors give better resolution at low pressure without giving up high-range headroom, and the BARO option can be added for absolute readings. The calibrator measures and sources mA, reads DC voltage and supports RTD thermometry through its True Ohm input.\u003c\/p\u003e\n\u003cp\u003eThe T-620H pump adds a vernier for precise final adjustments, a swivel-mounted reference gauge, a vent valve for pressure release and a 24-inch rubber hose with a 0.25 inch NPT connection to the device under test.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTwo isolated sensors: 1,000 psi and 3,000 psi\u003c\/li\u003e\n\u003cli\u003e0.035% of reading accuracy (18 to 28 °C)\u003c\/li\u003e\n\u003cli\u003eSystem range 0 to 5,000 psi \/ 350 bar with T-620H pump\u003c\/li\u003e\n\u003cli\u003eMeasures and sources mA with internal 24 VDC supply\u003c\/li\u003e\n\u003cli\u003eTrue Ohm thermometer input for RTD probes\u003c\/li\u003e\n\u003cli\u003eT-620H vernier, vent valve and swivel reference gauge\u003c\/li\u003e\n\u003cli\u003eNon-menu interface; stores and recalls screens\u003c\/li\u003e\n\u003cli\u003eTemperature compensated from -20 to 50 °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDual-range calibration of gauges and transmitters\u003c\/li\u003e\n\u003cli\u003emA loop calibration with pressure verification\u003c\/li\u003e\n\u003cli\u003eHydraulic bench calibration up to 5,000 psi\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat's in the Box\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHPC42-1KPSI\/3KPSI calibrator\u003c\/li\u003e\n\u003cli\u003eT-620H pump\u003c\/li\u003e\n\u003cli\u003eMPF-1\/4FPT, MPF-1\/4BSPF, MPF-CAP and MPM-PLUG fittings\u003c\/li\u003e\n\u003cli\u003eMPH-1 1 m CPF hose\u003c\/li\u003e\n\u003cli\u003eCustom carrying case\u003c\/li\u003e\n\u003cli\u003eBonded seals and Teflon tape\u003c\/li\u003e\n\u003cli\u003eReference gauge fittings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCrystal Engineering HPC42-1KPSI-3KPSI-CHX Pump System Technical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePressure sensors\u003c\/th\u003e\n\u003ctd\u003e1,000 psi and 3,000 psi gauge, isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSystem pressure range\u003c\/th\u003e\n\u003ctd\u003e0 to 5,000 psi \/ 350 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003ctd\u003e±0.035% of reading (18 to 28 °C); ±0.05% of reading (-20 to 50 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003emA input\u003c\/th\u003e\n\u003ctd\u003e0 to 55 mA, ±(0.015% of rdg + 0.002 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003emA output\u003c\/th\u003e\n\u003ctd\u003e0 to 25 mA, ±(0.015% of rdg + 0.002 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage input\u003c\/th\u003e\n\u003ctd\u003e0 to 30 VDC, ±(0.015% of rdg + 2 mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLoop power\u003c\/th\u003e\n\u003ctd\u003eFixed 24 VDC, 25 mA max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature input\u003c\/th\u003e\n\u003ctd\u003eRTD, 0 to 400 ohm, ±(0.015% of rdg + 0.02 ohm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003e320 x 240 pixel color graphical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure rating\u003c\/th\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBattery\u003c\/th\u003e\n\u003ctd\u003e4 x AA, over 12 h non-sourcing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePump hose\u003c\/th\u003e\n\u003ctd\u003e24-inch rubber, 0.25 inch NPT test connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003eManufacturer information: \u003ca href=\"https:\/\/www.ametekcalibration.com\/-\/media\/ametekcalibration\/download_links\/pressure\/hpc40\/digital-pressure-calibrator-hpc40-series-psi-data-sheet-us.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHPC40 Series datasheet on ametekcalibration.com\u003c\/a\u003e.\u003c\/p\u003e","brand":"Crystal Engineering","offers":[{"title":"Default Title","offer_id":67776882245819,"sku":"IMM_26327783","price":2360.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0777\/2635\/1547\/files\/crystal-engineering-hpc42-1kpsi-3kpsi-chx.jpg?v=1792555408","url":"https:\/\/indomultimeter.net\/products\/crystal-engineering-hpc42-1kpsi-3kpsi-chx-pump-system-dual-1000-3000-psi-sensors-with-t-620h-pump","provider":"Indo Multimeter","version":"1.0","type":"link"}