{"product_id":"cole-parmer-wd-35414-00-ph-conductivity-meter-oakton-pc-2700-2-to-20-ph-0-to-500-ms","title":"Cole-Parmer WD-35414-00 pH\/Conductivity Meter, Oakton PC 2700, -2 to 20 pH, 0 to 500 mS","description":"\u003ch2\u003eCole-Parmer WD-35414-00 pH\/Conductivity Meter, Oakton PC 2700, -2 to 20 pH, 0 to 500 mS\u003c\/h2\u003e\n\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe WD-35414-00 is a research-grade multiparameter benchtop meter in the Oakton 2700 Series, in a compact design roughly 40% smaller than earlier benchtop meters. Auto-standardization, auto-calibration and autoranging are standard, along with auto-buffer recognition for USA, NIST and DIN pH buffer sets and automatic or manual temperature compensation.\u003c\/p\u003e\n\u003cp\u003eCalibration and measurement can be protected with password-controlled setup, and a calibration-due alarm prevents working with outdated calibrations. Up to 500 data sets are stored in non-volatile memory with date and time stamps to meet GLP requirements, and data is exported to a printer or PC through the RS-232 port.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMeasures pH, ORP, ion, conductivity, TDS, salinity, resistivity and temperature\u003c\/li\u003e\n\u003cli\u003epH accuracy ±0.002 with 0.001\/0.01\/0.1 resolution and up to 6-point calibration\u003c\/li\u003e\n\u003cli\u003eConductivity range 0 to 500 mS with automatic or manual temperature compensation\u003c\/li\u003e\n\u003cli\u003eTDS, salinity and resistivity measurements with autoranging\u003c\/li\u003e\n\u003cli\u003e500-point memory with date\/time stamp for GLP documentation\u003c\/li\u003e\n\u003cli\u003eAuto-standardization, auto-calibration and calibration-due alarm\u003c\/li\u003e\n\u003cli\u003ePassword protection for setup and calibration menus\u003c\/li\u003e\n\u003cli\u003eIncludes pH electrode (WD-35805-04), conductivity\/temperature probe, stand and software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWater quality and environmental testing in the laboratory\u003c\/li\u003e\n\u003cli\u003eGeneral laboratory pH and conductivity analysis\u003c\/li\u003e\n\u003cli\u003eResearch and quality control requiring documented GLP data\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat's in the Box\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePC 2700 meter\u003c\/li\u003e\n\u003cli\u003eCombination pH electrode (WD-35805-04)\u003c\/li\u003e\n\u003cli\u003eConductivity\/temperature probe (WD-35412-10)\u003c\/li\u003e\n\u003cli\u003eUniversal 100-240 VAC power adapter\u003c\/li\u003e\n\u003cli\u003eElectrode arm and stand\u003c\/li\u003e\n\u003cli\u003ePC software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCole-Parmer WD-35414-00 pH\/Conductivity Meter, Oakton PC 2700, -2 to 20 pH, 0 to 500 mS Technical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003epH range\u003c\/th\u003e\n\u003ctd\u003e-2.000 to 20.000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003epH resolution\u003c\/th\u003e\n\u003ctd\u003e0.1 \/ 0.01 \/ 0.001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003epH accuracy\u003c\/th\u003e\n\u003ctd\u003e±0.002 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003emV range \/ accuracy\u003c\/th\u003e\n\u003ctd\u003e±2000 mV; ±0.2 mV or 0.05% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIon (ISE) range\u003c\/th\u003e\n\u003ctd\u003e0 to 19999 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConductivity range\u003c\/th\u003e\n\u003ctd\u003e0 to 500 mS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConductivity accuracy\u003c\/th\u003e\n\u003ctd\u003e±1% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTDS range\u003c\/th\u003e\n\u003ctd\u003e0 to 500 ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSalinity range\u003c\/th\u003e\n\u003ctd\u003e0 to 80 ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResistivity range\u003c\/th\u003e\n\u003ctd\u003e2.000 Ω to 20.0 MΩ, ±1% full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature range \/ accuracy\u003c\/th\u003e\n\u003ctd\u003e-10 to 110 °C; ±0.5 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDatalog memory\u003c\/th\u003e\n\u003ctd\u003e500 points with date\/time stamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInterfaces\u003c\/th\u003e\n\u003ctd\u003eRS-232 (2.5 mm jack); pH BNC input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower\u003c\/th\u003e\n\u003ctd\u003e100 to 240 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003eManufacturer information: \u003ca href=\"https:\/\/pim-resources.coleparmer.com\/instruction-manual\/oak2700.pdf\" target=\"_blank\" rel=\"noopener\"\u003e2700 Series instruction manual on coleparmer.com (PDF)\u003c\/a\u003e.\u003c\/p\u003e","brand":"Cole-Parmer","offers":[{"title":"Default Title","offer_id":67777179582651,"sku":"IMM_63762211","price":762.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0777\/2635\/1547\/files\/cole-parmer-wd-35414-00.jpg?v=1792557165","url":"https:\/\/indomultimeter.net\/products\/cole-parmer-wd-35414-00-ph-conductivity-meter-oakton-pc-2700-2-to-20-ph-0-to-500-ms","provider":"Indo Multimeter","version":"1.0","type":"link"}